PN2570
Pressure sensor with display
PN-400-SEG14-MFRKG/US/ /V
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN2570-00 — 16.06.2015 —
Electrical data
Operating voltage [V]
18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]
< 35
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
yes
Power-on delay time [s]
0.3
Integrated watchdog
yes
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs
2
Output signal
switching signal; analogue signal; IO-Link; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching
output DC
[V]
2
Permanent current rating of
switching output DC
[mA]
250
Switching frequency DC [Hz]
< 500
Number of analogue outputs
1
Analogue current output [mA]
4...20; (scalable 1:5)
Max. load [Ω]
500
Analogue voltage output [V]
0...10; (scalable 1:5)
Min. load resistance [Ω]
2000
Short-circuit protection
yes
Type of short-circuit
protection
pulsed
Overload protection
yes
Measuring/setting range
Measuring range 0...400 bar 0...5800 psi 0...40 MPa
Set point SP 1.5...400 bar 20...5800 psi 0.15...40 MPa
Reset point rP 1...399.5 bar 10...5790 psi 0.1...39.95 MPa
Analogue start point 0...320 bar 0...4640 psi 0...32 MPa
Analogue end point 80...400 bar 1160...5800 psi 8...40 MPa
In steps of 0.5 bar 10 psi 0.05 MPa
Accuracy / deviations
Switch point accuracy
[% of the span]
< ± 0,4; (Turn down 1:1)
Repeatability [% of the span]
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation
[% of the span]
< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL
= Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation
[% of the span]
< ± 0,1; (Turn down 1:1)
Long-term stability
< ± 0,05; (Turn down 1:1; per 6 months)